Transparent fill, border only, rectangle show up exactly as you configured them. Makes sense to me that the object on the top of the stack is the one it tries to interact with, unless the system does a lot of work to try to guess what the user really wants.ĭotted fill makes sense for invisible buttons because they are still clickable in that area. That project file is for a small Robot cell but the project data as of today is over 4gig big. Siemens have had looks at it but can't understand why it's acting the way it do. I have an old V12 project the accumulates the compiled data. Remove this map and run a compile all again. I've also experienced this problem with I/O fields displaying temperature, pressure et.cġ) Allways run a Compile all of the projects.Ģ) In the TIA project folder you have a map Called IM. All the connections to the Pushbutton in the HMI were correct but long story short the compiler messes up the connection points. When I pressed Start Fan, a conveyor started. In the HMI we have a manual page for controlling the objects in the machine manually. We had a machine with some conveyors fans and other equipment. but it's just one of those things you get to live with. There is an known (?) bug in the complier at least when working with Comfort or WinCC Unified HMIs.